{"id":13045,"date":"2023-12-06T18:58:48","date_gmt":"2023-12-06T18:58:48","guid":{"rendered":"https:\/\/introspect.ca\/blog\/5-things-you-need-to-know-about-the-i3c-purvue-analyzer-embedded-real-time-oscilloscope\/"},"modified":"2026-06-28T01:59:06","modified_gmt":"2026-06-28T01:59:06","slug":"5-things-you-need-to-know-about-the-i3c-purvue-analyzer-embedded-real-time-oscilloscope","status":"publish","type":"blogposts","link":"https:\/\/introspect.ca\/fr\/blog\/5-things-you-need-to-know-about-the-i3c-purvue-analyzer-embedded-real-time-oscilloscope\/","title":{"rendered":"5 choses \u00e0 savoir sur l&rsquo;oscilloscope en temps r\u00e9el int\u00e9gr\u00e9 PurVue Analyzer\u00ae"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">Lourd, encombrant et co\u00fbteux. Je se pr\u00e9sente sous la forme d\u2019un bo\u00eetier de table dot\u00e9 d\u2019un \u00e9cran d\u2019affichage, et beaucoup disent que je ressemble \u00e0 un vieux t\u00e9l\u00e9viseur ou \u00e0 un micro-ondes. Qui suis-je ? Si vous avez devin\u00e9 qu\u2019il s\u2019agit d\u2019un oscilloscope classique, vous avez trouv\u00e9 la bonne r\u00e9ponse ! Cependant, nous ne sommes pas ici aujourd\u2019hui pour parler de la complexit\u00e9 d\u2019un oscilloscope ni de la quantit\u00e9 de travail manuel n\u00e9cessaire \u00e0 sa configuration. Bien au contraire. Il est temps pour vous de d\u00e9couvrir le PurVue Analyzer d\u2019Introspect Technology      <\/span><span style=\"font-weight: 400;\">\u00ae <\/span><span style=\"font-weight: 400;\">, oscilloscope temps r\u00e9el int\u00e9gr\u00e9 au <a href=\"https:\/\/introspect.ca\/fr\/blog\/5-things-you-need-to-know-about-the-i3c-purvue-analyzer-embedded-real-time-oscilloscope\/\">module de test num\u00e9rique \u00e0 moyenne fr\u00e9quence SV6E-X<\/a>.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">L&rsquo; <\/span><a href=\"https:\/\/introspect.ca\/product\/i3c-purvue-analyzer\/\"><span style=\"font-weight: 400;\">PurVue Analyzer<\/span><\/a><a href=\"https:\/\/introspect.ca\/product\/i3c-purvue-analyzer\/\">\u00ae<\/a><span style=\"font-weight: 400;\"> \u2014 qui se prononce \u00ab pure view \u00bb \u2014 est issu du module de test num\u00e9rique \u00e0 moyenne fr\u00e9quence SV6E-X, une solution tout-en-un destin\u00e9e au d\u00e9veloppement et aux tests d\u2019interfaces num\u00e9riques \u00e0 moyenne fr\u00e9quence, combinant un g\u00e9n\u00e9rateur de protocole, un analyseur de protocole et un programmateur de p\u00e9riph\u00e9riques. Le PurVue Analyzer<\/span><span style=\"font-weight: 400;\">\u2122<\/span><span style=\"font-weight: 400;\"> est donc un composant optionnel mais essentiel du SV6E-X. Ce produit permet aux utilisateurs d\u2019obtenir une vue en temps r\u00e9el et en un seul coup de tous les signaux <a href=\"https:\/\/www.mipi.org\/specifications\/i3c-sensor-specification\" target=\"_blank\" rel=\"noopener\">I3C<\/a>.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">En bref, l&rsquo;analyseur PurVue<\/span><span style=\"font-weight: 400;\">\u2122<\/span><span style=\"font-weight: 400;\"> est un oscilloscope en temps r\u00e9el int\u00e9gr\u00e9 de 500 MHz, 12 bits, d\u00e9clench\u00e9 par le protocole I3C, dot\u00e9 de 2 canaux simultan\u00e9s. Il permet la mesure interne des signaux SCL et SDA au sein du module de test num\u00e9rique \u00e0 moyenne fr\u00e9quence portable SV6E-X<\/span><span style=\"font-weight: 400;\">, ce qui \u00e9limine le recours \u00e0 des sondes actives externes ou \u00e0 des oscilloscopes de table. De plus, la configuration est intuitive gr\u00e2ce au logiciel Pinetree.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">  Il est apparu de plus en plus clairement qu\u2019un oscilloscope convivial \u00e9tait n\u00e9cessaire pour r\u00e9pondre aux besoins de nos clients et fluidifier l\u2019ensemble des processus de test par rapport aux m\u00e9thodes actuelles. C&rsquo;est pourquoi, soucieuse de l&rsquo;exp\u00e9rience client et de l&rsquo;efficacit\u00e9, Introspect Technology s&rsquo;est attach\u00e9e \u00e0 cr\u00e9er un produit comblant une lacune majeure en mati\u00e8re de disponibilit\u00e9 des \u00e9quipements pour la validation, la caract\u00e9risation et le d\u00e9bogage au niveau syst\u00e8me des impl\u00e9mentations bas\u00e9es sur l&rsquo;I3C. <\/span><\/p>\n<h3><strong>Les 5 fonctionnalit\u00e9s du PurVue Analyzer\u00ae <\/strong><strong>que vous devez conna\u00eetre :<\/strong><\/h3>\n<p><b>1. Bande passante, fr\u00e9quence d&rsquo;\u00e9chantillonnage et r\u00e9solution :<\/b> <span style=\"font-weight: 400;\">Le PurVue Analyzer\u00ae <\/span> <span style=\"font-weight: 400;\">offre une bande passante de 500 MHz, un taux d\u2019\u00e9chantillonnage de 1 Gsps et une r\u00e9solution de 12 bits sur deux canaux simultan\u00e9s (un pour SCL et un pour SDA). Il s\u2019agit l\u00e0 de performances de haut niveau pour un appareil de table, qui ne n\u00e9cessite m\u00eame pas de sondes actives externes.<\/span><\/p>\n<p><b>2. D\u00e9clenchements mat\u00e9riels bas\u00e9s sur les protocoles :<\/b> cet oscilloscope embarqu\u00e9 fonctionne \u00e0 l\u2019oppos\u00e9 du d\u00e9codage de protocole des oscilloscopes classiques. Il est bas\u00e9 sur les protocoles dans la mesure o\u00f9 il peut \u00eatre d\u00e9clench\u00e9 par le c\u0153ur complet de l\u2019analyseur de protocoles du SV6E-X et exploite l\u2019ensemble de la liste des d\u00e9clencheurs d\u2019\u00e9v\u00e9nements. Le PurVue Analyzer\u00ae offre un contr\u00f4le complet, bas\u00e9 sur les protocoles, du moment o\u00f9 capturer une forme d\u2019onde en temps r\u00e9el. Par exemple, l\u2019utilisateur peut programmer le SV6E-X pour qu\u2019il commence la capture d\u00e8s qu\u2019une transaction X est d\u00e9tect\u00e9e sur le bus.   <\/p>\n<p><b>3. Corr\u00e9lation temporelle exacte entre les signaux analogiques et num\u00e9riques :<\/b><span style=\"font-weight: 400;\"> Le nouvel oscilloscope int\u00e9gr\u00e9 permet d\u2019effectuer <\/span><span style=\"font-weight: 400;\">des mesures analogiques et num\u00e9riques parfaitement corr\u00e9l\u00e9es dans le temps au sein d\u2019un seul et m\u00eame instrument. Cela permet d\u2019obtenir une <\/span><span style=\"font-weight: 400;\">vue en temps r\u00e9el et en une seule prise de tous les signaux I3C. La mesure de signaux d\u2019une puret\u00e9 irr\u00e9prochable, sans artefacts dus \u00e0 des sondes captant le bruit des signaux Wi-Fi ou RF, permet \u00e0 l\u2019utilisateur d\u2019obtenir des r\u00e9sultats de mesure plus pr\u00e9cis. Mieux encore, cela \u00e9limine le recours \u00e0 un oscilloscope de table classique et \u00e0 des sondes actives externes. <\/span> <\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-7720 alignleft\" src=\"https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-300x141.jpg\" alt=\"\" width=\"861\" height=\"405\" srcset=\"https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-300x141.jpg 300w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-1024x480.jpg 1024w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-768x360.jpg 768w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-1536x720.jpg 1536w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-600x281.jpg 600w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-128x60.jpg 128w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit-192x90.jpg 192w, https:\/\/introspect.ca\/wp-content\/uploads\/2022\/07\/TimeCorrelation_PurVue-Screenshots_2048x960_edit.jpg 2048w\" sizes=\"auto, (max-width: 861px) 100vw, 861px\" \/><\/p>\n<p><b>4. Facile \u00e0 utiliser :<\/b><span style=\"font-weight: 400;\"> Que diriez-vous de r\u00e9aliser vos tests de mesure de signal depuis chez vous, ou depuis n\u2019importe quel endroit disposant d\u2019une prise \u00e9lectrique ? C\u2019est exact : le SV6E-X et le PurVue Analyzer tiennent dans votre sac et s\u2019installent facilement n\u2019importe o\u00f9 \u00e0 l\u2019aide d\u2019un ordinateur portable. Le PurVue Analyzer\u00ae <\/span><span style=\"font-weight: 400;\"> est enti\u00e8rement int\u00e9gr\u00e9 au logiciel <a href=\"https:\/\/introspect.ca\/fr\/product\/pinetree\/\">Pinetree<\/a> et permet un fonctionnement interactif ou une automatisation compl\u00e8te. Dans l\u2019ensemble, ce produit a \u00e9t\u00e9 con\u00e7u en mettant l\u2019accent sur l\u2019exp\u00e9rience utilisateur afin de faciliter la collecte des donn\u00e9es.<\/span><\/p>\n<p><b>5. Traitement math\u00e9matique illimit\u00e9 :<\/b><span style=\"font-weight: 400;\"> Il exploite les biblioth\u00e8ques Python int\u00e9gr\u00e9es au logiciel Pinetree pour offrir un contr\u00f4le total sur les types de mesures effectu\u00e9es. L\u2019ensemble du traitement est effectu\u00e9 automatiquement par le logiciel. Gr\u00e2ce \u00e0 la flexibilit\u00e9 de cet outil, les utilisateurs peuvent \u00e9galement enregistrer des donn\u00e9es brutes et les traiter ult\u00e9rieurement eux-m\u00eames si n\u00e9cessaire.<\/span><\/p>\n<h3><b>Solution compl\u00e8te de test I3C<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Comme si le SV6E-X n&rsquo;\u00e9tait pas d\u00e9j\u00e0 un produit de g\u00e9nie, l&rsquo;ajout de l&rsquo;oscilloscope en temps r\u00e9el int\u00e9gr\u00e9 en fait une solution compl\u00e8te pour les tests et la caract\u00e9risation complexes, ainsi que pour la validation de la conception des interfaces I3C. L&rsquo;analyseur PurVue<\/span><span style=\"font-weight: 400;\">\u00ae <\/span><span style=\"font-weight: 400;\"> est d\u00e9sormais disponible sous forme de mise \u00e0 niveau pour les appareils SV6E-X existants, ou peut \u00eatre s\u00e9lectionn\u00e9e en option lors de l\u2019achat d\u2019un nouvel appareil SV6E-X. Cet nouvel oscilloscope portable en est peut-\u00eatre \u00e0 ses d\u00e9buts, mais ses capacit\u00e9s, attendues depuis longtemps, repr\u00e9sentent l\u2019avenir des tests et des mesures I3C.<\/span><\/p>\n<p>Vous souhaitez en savoir plus sur le <span style=\"font-weight: 400;\">PurVue Analyzer\u00ae<\/span><span style=\"font-weight: 400;\">? Envoyez-nous un e-mail \u00e0 l&rsquo;adresse <a href=\"mailto:info@introspect.ca\" target=\"_blank\" rel=\"noopener\">info@introspect.ca<\/a>.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Il est apparu de plus en plus clairement qu\u2019un oscilloscope convivial \u00e9tait n\u00e9cessaire pour r\u00e9pondre aux besoins de nos clients et fluidifier l\u2019ensemble des processus de test par rapport aux m\u00e9thodes actuelles. C&rsquo;est pourquoi, soucieuse de l&rsquo;exp\u00e9rience client et de l&rsquo;efficacit\u00e9, Introspect Technology s&rsquo;est attach\u00e9e \u00e0 cr\u00e9er un produit comblant une lacune majeure en mati\u00e8re de disponibilit\u00e9 des \u00e9quipements pour la validation, la caract\u00e9risation et le d\u00e9bogage au niveau syst\u00e8me des impl\u00e9mentations bas\u00e9es sur l&rsquo;I3C. <\/p>\n","protected":false},"author":19,"featured_media":7730,"menu_order":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"class_list":["post-13045","blogposts","type-blogposts","status-publish","has-post-thumbnail","hentry","blog_topics-perspectives-techniques","blog_tags-oscilloscope","blog_tags-protocol-analyzer","blog_tags-i3c","blog_tags-purvue-analyzer"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/blogposts\/13045","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/blogposts"}],"about":[{"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/types\/blogposts"}],"author":[{"embeddable":true,"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/users\/19"}],"version-history":[{"count":1,"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/blogposts\/13045\/revisions"}],"predecessor-version":[{"id":13046,"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/blogposts\/13045\/revisions\/13046"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/media\/7730"}],"wp:attachment":[{"href":"https:\/\/introspect.ca\/fr\/wp-json\/wp\/v2\/media?parent=13045"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}